The keypad will display the number and type of modules it detected and enrolled. The system will then go through and automatically enroll any keypads and modules to the next available slot on the system. This is what we want so you can press * or enter 000 to go into that subsection. The keypad will display subsection 000 Auto Enroll. To enroll all the modules that you have attached you will need to go to section 902. And Program Labels is the name of section 000. The arrows just indicate that you can scroll with the arrow keys. The number in parentheses is the section number. The keypad will display Select (000) Program Labels. Step 3: Enroll Additional Keypads and Modules Īfter enrolling the first keypad you can now begin programming.Įnter programming (*85555). You will then need to start over on all programming.

#Vera dsc alarm panel force stay arm how to

Whatever the reason is, for guidance on how to default the panel: see Appendix A. Or at some later point if you make some mistake that you cannot determine how to undo. You may wish to default the panel to ensure you have a clean slate to start with. The screen may display some error messages for about a minute or two while the system is fully booting such as: Panel response not received. Once you press a key, the first keypad will be enrolled into the first slot automatically. Once the system is loaded the keypad should display: Press any key to enroll. Power up the system by plugging in the AC power transformer and then attaching the backup battery. This will help ensure that you have hardwired zones available for expansion without needing to reprogram anything. We recommend, in most cases, using the first zones for hardwired devices and leaving any zones that have hardwired terminals available reserved for hardwired devices. It is also extremely helpful to have all your zones written out and in front of you during programming so that you can easily reference it. For wireless sensors, it is useful to have them laid out nearby for enrollment purposes. We recommend getting all your hardwired components in place and wired to the main board before programming.

#Vera dsc alarm panel force stay arm code

If at anytime you get lost, STOP, and hit #, and then start over.Įntering Programming: *8 - Installer Code If you get a long beep, the system did not like what you entered. A quick triple beep means the system accepted you entry and is now ready for the next entry. If using an LED or ICON keypad, you will not see a display or any numbers during your programming. These keypads will allow you to see what section are in and what you enter and this quick start guide will assume you have one. NOTE: We heavily recommend programming using a LCD keypad. Doing so may cause problems in the function of your alarm system. WE DO NOT RECOMMEND BEING IN ANY PROGRAMMING SECTION THAT IS NOT IN THIS GUIDE UNLESS YOU FULLY UNDERSTAND THE FUNCTION OF THAT SECTION. Total Connect 2.0 Package Monitoring Add-Onsĭownload the DSC PowerSeries NEO (HS2016, HS2032, HS2064, HS2128) Quickstart HERE.Central Station Alarm Monitoring Services.Is there a way to change the vendorstatuscode and VendorStatus in order to trick the system into thinking the alarm is Ready instead of Ready - Force Arming. I’m wondering if there is a way to send the request via Luup directly to the envisalink (via PLEG) in order to bypass the DSC plugin. All of their attributes are set to be force armable and bypassable. I have three 24hr non alarm zones in my partition. I need a away around this! I need to arm with pin in order to track which users are arming, so quickarm is not an option. It seems like the DSC plugin reads the vendor state 653 (Ready to Force Arm) as though the pannel is not ready to arm. Luup_log:171: DSCAlarmPanel: debug Panel::System Error (Partition is Not Ready to Arm) This is the error message i get from the logs: When trying to Arm the system from vera when there is a force armable zone open you get a “SYSTEM NOT READY” message in the vera logs. From there system automaticly arms to away mode when there is an open (force armable) zone. From the Envisalink mobile link/website force arming works fine. Has anyone figured this out yet? I have been trying for weeks to get force arming to work from vera.














Vera dsc alarm panel force stay arm